High-Voltage Capacitors

Single-Phase High-Voltage Shunt Capacitors

HAOQI supplies single-phase high-voltage shunt capacitors for AC reactive power compensation. This page brings together product photographs and model data. Single-phase units can also form banks for three-phase systems; verify connections, insulation and installation against the project and confirmed drawings.

Verify terminal connections, insulation and mounting dimensions for the selected model and confirmed drawings. Harmonic-filter duty requires a system-specific review.

Photographs show series configurations. Confirm construction and dimensions against the selected model drawing.

Rated Voltage (Un)5.5–13.8 kV
Reactive Power (Qn)200–667 kvar
Capacitance (Cn)2.79–70.2 μF

Ranges describe the series. See the model table for individual ratings; project requirements are confirmed separately.

Applications

  • Distribution networks
  • Industrial PFC
  • AC system shunt compensation
  • HV substations
  • Harmonic filtering, subject to system review

Technical specifications

ParameterValue
Rated Voltage (Un)5.5–13.8 kV
Reactive Power (Qn)200–667 kvar
Capacitance (Cn)2.79–70.2 μF
Rated Frequency (Fn)50 / 60 Hz
ConfigurationSingle-phase; connections and installation confirmed by model
StandardsGB/T 11024 · IEC 60871

Product models

The catalogue notation 50(60) Hz does not confirm that the same ratings apply at both frequencies. Confirm frequency, capacitance and reactive power together for the ordered version.

“—” means the original data does not list the value; it does not mean zero. Confirm missing values for the selected model.

L, W, H, h and h1 follow the selected model drawing. H may be the case height, not the overall height including terminals; confirm the full installation envelope and clearances.

RecordModelUn (kV)Qn (kVAR)Fn (Hz)In (A)Cn (μF)Weight (kg)L (mm)W (mm)h (mm)h1 (mm)H (mm)
HV-SP-001BAM13.8-200-1W-1P13.820050(60)14.52.79—343138——430Enquire
HV-SP-002BAM13.8-500-1W-1P13.850050(60)36.26.97—383179——650Enquire
HV-SP-003BAM11/√3-200-1W11/√320050(60)—15.836.5343138100475705Enquire
HV-SP-004BAM11/√3-300-1W11/√330050(60)—23.748.5343178200525835Enquire
HV-SP-005BAM11/√3-334-1W11/√333450(60)—26.452343178200550860Enquire
HV-SP-006BAM11/√3-417-1W11/√341750(60)—32.9643431782007001010Enquire
HV-SP-007BAM11/√3-500-1W11/√350050(60)—39.571.53431782008001110Enquire
HV-SP-008BAM11/√3-667-1W11/√366750(60)—52.69034317820010251335Enquire
HV-SP-009BAM12/√3-200-1W12/√320050(60)—13.336.5343138100475705Enquire
HV-SP-010BAM12/√3-334-1W12/√333450(60)—22.152343178200550860Enquire
HV-SP-011BAM12/√3-417-1W12/√341750(60)—27.7643431782007001010Enquire
HV-SP-012BAM12/√3-500-1W12/√350050(60)—33.271.53431782008001110Enquire
HV-SP-013BAM12/√3-667-1W12/√366750(60)—44.29034317820010251335Enquire
HV-SP-014BAM11/2-334-1W11/233450(60)—35.152343178200550860Enquire
HV-SP-015BAM11/2-417-1W11/241750(60)—43.9643431782007001010Enquire
HV-SP-016BAM11/2-500-1W11/250050(60)—52.671.53431782008001110Enquire
HV-SP-017BAM11/2-667-1W11/266750(60)—70.29034317820010251335Enquire
HV-SP-018BAM12/2-334-1W12/233450(60)—29.552343178200550860Enquire
HV-SP-019BAM12/2-417-1W12/241750(60)—36.9643431782007001010Enquire
HV-SP-020BAM12/2-500-1W12/250050(60)—44.271.53431782008001110Enquire
HV-SP-021BAM12/2-667-1W12/266750(60)—599034317820010251335Enquire
HV-SP-022BAM13/2-334-1W13/233450(60)—25.252343178200550860Enquire
HV-SP-023BAM13/2-417-1W13/241750(60)—31.4643431782007001010Enquire
HV-SP-024BAM13/2-500-1W13/250050(60)—37.771.53431782008001110Enquire
HV-SP-025BAM13/2-667-1W13/266750(60)—50.39034317820010251335Enquire
HV-SP-026BAM11-417-1W1141750(60)—11643431782007001010Enquire
HV-SP-027BAM11-500-1W1150050(60)—13.271.53431782008001110Enquire
HV-SP-028BAM11-667-1W1166750(60)—17.59034317820010251335Enquire
HV-SP-029BAM12-500-1W1250050(60)—11.171.53431782008001110Enquire
HV-SP-030BAM12-667-1W1266750(60)—14.79034317820010251335Enquire
HV-SP-031BAM13-500-1W1350050(60)—9.471.53431782008001110Enquire
HV-SP-032BAM13-667-1W1366750(60)—12.69034317820010251335Enquire
Un (kV) — Rated voltageQn (kVAR) — Reactive powerFn (Hz) — FrequencyIn (A) — Rated currentCn (μF) — CapacitanceL (mm) — Dimension L (see model drawing)W (mm) — Dimension W (see model drawing)H (mm) — Height H (see model drawing)

Selection guidance

Confirm electrical and operating conditions
Specify single- or three-phase capacitor units and verify system connections, rated voltage, frequency, capacitance and reactive power.
Check configuration and mounting interfaces
Verify terminal connections, insulation and mounting dimensions for the selected model and confirmed drawings. Harmonic-filter duty requires a system-specific review.
Documents and quotation
Provide the model or application, quantity, destination and required documents. Use the manufacturer and document checks to confirm drawing revisions and document ownership. See catalogs and documents for current availability; provision is confirmed by product.
Request a quote

Frequently asked questions

Can single-phase units be used in a three-phase system?
Single-phase units can form a three-phase capacitor bank, with connections, quantity, protection and ratings confirmed by the project design. A three-phase unit integrates all three phases.
How are connection and installation requirements confirmed?
Provide the selected model, nameplate and existing drawings. Verify terminal connections, insulation, overall dimensions and mounting requirements against confirmed drawings.

Have a specific requirement?

Ask HAOQI to coordinate specification review or request the relevant product documents.